SV-ADAHRS-200/201 Installation and Configuration
SkyView System Installation Guide - Revision R 5-7
If the OAT probe is installed correctly, there should be an outside air temperature reading on
the PFD.
Adjusting OAT Offset
SkyView provides the ability to adjust the displayed OAT +/- 20F (11.1C). This adjustment is
applied across the OAT’s entire temperature range. This adjustment can be made under SETUP
MENU >HARDWARE CALIBRATION > ADAHRS CALIBRATION > OAT OFFSET.
Dynon D10/D100 Series OAT Probes
If your aircraft already has a Dynon Avionics OAT installed from an older Dynon Avionics
product, and you do not want to reinstall the SV-OAT-340 in its place (difficult access, etc.), it is
possible to use the older OAT with SkyView. Cut off as much wire as needed from the SV-OAT-
340 - you will use the White w/Black wires with pins pre-crimped, and the connector.
If your plane has a Dynon Avionics 100433-000 OAT installed (typically connected to the 37-
pin EMS connector, two White w/Black Stripe wires), simply connect either White w/Black
Stripe wire on the installed OAT with one of the wires from the SV-OAT-340. The OAT is not
polarity-sensitive.
If your plane has a Dynon Avionics 100433-001 OAT installed (typically connected to the
EDC-D10A remote compass, shielded cable with Blue, Red, and Yellow wires):
o Tape, heat shrink, or otherwise isolate the shield - it will not be used.
o Tape, heat shrink, or otherwise isolate the Red wire - it will not be used.
o Connect the Blue wire to either White w/Black Stripe wire (not polarity sensitive)
o Connect the Yellow wire to the other White w/Black Strip wire (not polarity
sensitive) from the SV-OAT-340.
PFD-Related Settings
Once the physical ADAHRS installation is complete, it may be necessary to configure PFD-
related ADAHRS settings for the SkyView system. All ADAHRS settings are automatically shared
between displays in multi-display systems.
Measurement Units
Set altitude, distance and speed, temperature, barometer, and pressure measurement units as
detailed in the How to Configure Displayed Units Section of this guide.
ADAHRS Source Selection and Configuration
SkyView systems support multiple SV-ADAHRS-200/201 modules for redundancy and manage
failure scenarios by automatically switching to backup modules should an ADAHRS completely
fail.
Additionally, in the event that multiple ADAHRS disagree, the display will annunciate this with
an on-screen alert that calls out which parameter(s) are not the same on all ADAHRS. The