SV-EMS-220/221 Installation and Configuration
SkyView System Installation Guide - Revision R 7-67
Example Voltmeter Setup
Assume this sensor was mapped on the Sensor Input Mapping Wizard as:
PIN #
FUNCTION
SENSOR
NAME
C37 P1
VOLTS
VOLTAGE MEASURE
MAIN
Now, we want to configure its alert and graphical properties. Go to the Sensor Setup Menu and
open the MAIN VOLTS Page (SETUP MENU > EMS SETUP > SENSOR SETUP > MAIN VOLTS).
Configure MAIN VOLTS with the following properties:
ALARM: OFF
MAXIMUM GRAPHICAL DISPLAY: 15.0 VOLTS
MINIMUM GRAPHICAL DISPLAY: 10.0 VOLTS
SHOW SENSOR UNITS YES
RANGE 1
o ENABLE YES
o COLOR RED
o TOP 11.0 VOLTS
o BOTTOM 10.0 VOLTS
RANGE 2
o ENABLE YES
o COLOR YELLOW
o TOP 12.0 VOLTS
o BOTTOM 11.0 VOLTS
RANGE 3
o ENABLE YES
o COLOR GREEN
o TOP 13.6 VOLTS
o BOTTOM 12.0 VOLTS
RANGE 4
o ENABLE YES
o COLOR YELLOW
o TOP 14.6 VOLTS
o BOTTOM 13.6 VOLTS
RANGE 5
o ENABLE YES
o COLOR RED
o TOP 15.0 VOLTS
o BOTTOM 14.6 VOLTS
Figure 46Anatomy of a Widget:
Main Volts
Page view 174
1 2 ... 170 171 172 173 174 175 176 177 178 179 180 ... 400 401