SV-EMS-220/221 Installation and Configuration
SkyView System Installation Guide - Revision R 7-67
Example Voltmeter Setup
Assume this sensor was mapped on the Sensor Input Mapping Wizard as:
Now, we want to configure its alert and graphical properties. Go to the Sensor Setup Menu and
open the MAIN VOLTS Page (SETUP MENU > EMS SETUP > SENSOR SETUP > MAIN VOLTS).
Configure MAIN VOLTS with the following properties:
ALARM: OFF
MAXIMUM GRAPHICAL DISPLAY: 15.0 VOLTS
MINIMUM GRAPHICAL DISPLAY: 10.0 VOLTS
SHOW SENSOR UNITS YES
RANGE 1
o ENABLE YES
o COLOR RED
o TOP 11.0 VOLTS
o BOTTOM 10.0 VOLTS
RANGE 2
o ENABLE YES
o COLOR YELLOW
o TOP 12.0 VOLTS
o BOTTOM 11.0 VOLTS
RANGE 3
o ENABLE YES
o COLOR GREEN
o TOP 13.6 VOLTS
o BOTTOM 12.0 VOLTS
RANGE 4
o ENABLE YES
o COLOR YELLOW
o TOP 14.6 VOLTS
o BOTTOM 13.6 VOLTS
RANGE 5
o ENABLE YES
o COLOR RED
o TOP 15.0 VOLTS
o BOTTOM 14.6 VOLTS
Figure 46—Anatomy of a Widget:
Main Volts