System Planning
2-2 SkyView System Installation Guide - Revision R
Power Consumption
Table 2 contains power specifications for typical SkyView systems. Note that SkyView displays
(SV-D700, SV-D1000, SV-D1000T) provide power to SkyView Network modules, thus the
modules are not included in this table. When there are two SkyView displays in a system, both
displays “share the load” of powering SkyView Network modules. Other units listed below are
powered independently from the SkyView display.
Approximate current
consumption
12 volt DC system
Approximate current
consumption
24 volt DC system
Circuit Breaker
1
Recommendation
SV-D700 / SV-D1000
(per display
2
)
3.5A average
(SV-BAT-320 not
installed)
5.0A average
3
(SV-BAT-320 installed,
when charging)
2.5A with battery
4
(SV-BAT-320 installed,
when charging)
3.1A average
(SV-BAT-320 not
installed)
4.6A average
6
(SV-BAT-320 installed,
when charging)
2.3A with battery
7
(SV-BAT-320 installed,
when charging)
4.0A maximum
(depends on the trim
motors used)
2.0A average
(transmitting)
1.0A average
(transmitting)
1.3A (moving 100%
torque)
0.7A (moving 100%
torque)
2.0 A (moving 100%
torque)
1.0 A (moving 100%
torque)
Circuit breaker recommendation is the smallest circuit breaker that is commonly available in certified versions.
When multiple SkyView displays are installed, each display contributes to powering SkyView Network modules
5.0A average when charging a discharged battery, 3.5A average when battery is fully charged
2.5A average when charging a discharged battery, 1.8A average when battery is fully charged
When multiple SkyView displays are installed, each display contributes to powering SkyView Network modules
4.6A average when charging a discharged battery, 3.1A average when battery is fully charged
2.3A average when charging a discharged battery, 1.6A average when battery is fully charged
Includes SV32, SV32C, SV32L
Includes SV42, SV42C, SV42EL, SV42L, SV42T