SV-GPS-250 Installation and Configuration
SkyView System Installation Guide - Revision R 8-3
curved surfaces. For extra protection, you may use weather sealant around the outside of the
SV-GPS-250 module where it meets the skin of the aircraft.
Serial Connection
SkyView uses the SV-GPS-250 device set to POS 1 as its primary position source.
The SV-GPS-250 includes 18 feet of twisted wire for a serial connection to the SkyView display
via the display. This wire may be trimmed or lengthened as needed to suit the installation.
The color of the SV-GPS-250 wires matches the colors of the wires of the main display harness
that are intended for the GPS serial connection. The following table contains information
regarding the wires.
Harness and SV-GPS-
250 Wire Color
SV-GPS-250 Tx /
Serial Port 5 Rx
SV-GPS-250 RX /
Serial Port 5 Tx
Table 40–SV-GPS-250 Serial Connection Details
As mentioned before, if there are two or more displays in your SkyView system, all four of the
SV-GPS-250 module’s wires must be connected to all displays in parallel. This wiring scheme is
illustrated in Figure 55.