SV-EMS-220/221 Installation and Configuration
SkyView System Installation Guide - Revision R 7-69
Example RPM Setup
Assume this sensor was mapped on the Sensor Input Mapping Wizard as:
Now, we want to configure its alert and graphical properties. Go to the Sensor Setup Menu and
open the RPM Page (SETUP MENU > EMS SETUP > SENSOR SETUP > RPM RPM).
Configure RPM with the following properties:
ALARM: OFF
MAXIMUM GRAPHICAL DISPLAY: 3000 RPM
MINIMUM GRAPHICAL DISPLAY: 0 RPM
SHOW SENSOR UNITS YES
RANGE 1
o ENABLE YES
o COLOR GREEN
o TOP 2000 RPM
o BOTTOM 0 RPM
RANGE 2
o ENABLE YES
o COLOR YELLOW
o TOP 2250 RPM
o BOTTOM 2000 RPM
RANGE 3
o ENABLE YES
o COLOR GREEN
o TOP 2700 RPM
o BOTTOM 2250 RPM
RANGE 4
o ENABLE YES
o COLOR YELLOW
o TOP 2750 RPM
o BOTTOM 2700 RPM
RANGE 5
o ENABLE YES
o COLOR RED
o TOP 3000 RPM
o BOTTOM 2750 RPM