VAL Avionics NAV 2000 Installation Guide Page 142

  • Download
  • Add to my manuals
  • Print
  • Page
    / 401
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 141
SV-EMS-220/221 Installation and Configuration
7-34 SkyView System Installation Guide - Revision R
o Available from http://www.bandcspecialty.com (316) 283-8000 part number
RCT-1
Weather Pack crimp tool (common slip joint pliers will also work)
o Available from http://www.whiteproducts.com/tools.shtml
#2 Phillips screwdriver
Flathead screwdriver
¼ID tubes, any necessary adapters, and clamps for routing manifold pressure to the
sensor.
Drill and 1/8bit
Voltmeter Inputs
Pins 1 and/or Pin 2 of the EMS D37 connector can be used to monitor voltage in your electrical
system (or any other DC voltage source) from 10-30V DC. Connect either of the pins to a point
in your electrical system that you wish to monitor.
Exhaust Gas Temperature (EGT) Probes
Correct placement of EGT probes on the exhaust manifold - per the engine manufacturer’s
guidance - is critical to obtaining accurate readings. Placement differs between engine types
and even specific models. All thermocouple harnesses supplied by Dynon have each function
(e.g., CHT1, EGT1) labeled on each thermocouple pair.
Rotax 912 (except 912 iS)
For carbureted Rotax 912 engines, only two of the four cylinders are typically monitored for
EGT. Unlike the CHT probes which are mounted on diagonal cylinders, the EGT probes should
be mounted on the two rear cylinders’ exhaust manifolds. It is critical that the EGT probes be
mounted to parallel cylinders’ exhaust manifolds for proper temperature comparison.