SV-D700, SV-D1000 and SV-D1000T Operation
SkyView Pilot’s User Guide - Revision Q 3-11
of emergency. Charging a completely discharged battery may take up to 4 hours. To conserve
your aircraft battery, the SV‐BAT‐320 is only charged when SkyView detects that your alternator
or generator is online. Specifically:
If SkyView system voltage is above 12.25V: SkyView runs on master power and charges
the SV-BAT-320.
If SkyView system voltage is above 10V, but below 12.25V: SkyView runs on master
power but does not charge the SV-BAT-320.
If SkyView system voltage is below 10V: SkyView runs on the SV-BAT-320. This
discharges the SV-BAT-320.
Reference the SkyView System Installation Guide for more details regarding current
consumption while charging a backup battery.
A battery is fully charged when it reaches 12.25 volts and should power a typical
SkyView system for at least 60 minutes. If SkyView has switched to the backup
battery due to a power loss in your aircraft, it is advised that you land as soon as
possible.
Backup Battery Status
SkyView performs an automatic 30 second self-test of the battery every time a SkyView is shut
down normally when master power is turned off after a flight. Additionally, a manually-
actuated discharge test should be performed annually when prompted by SkyView.
A battery status icon in the top bar and alert messages let you know when SkyView’s backup
battery is not operating nominally. These indications are as follows:
No battery icon displayed
No battery has been connected to this display or battery status is normal. If a battery is
connected, and no icon is displayed, all of the following are true:
o The Annual Backup Battery Test is not yet due.
o The self-test routine has not discovered abnormal behavior. Backup battery self-
tests are performed automatically every time master power is removed on the
ground (after a flight, for example) while the 30-second “power lost” timer is
counting down.
Needs test:
Figure 7 - Backup Battery Test Needed
SkyView has determined that the backup battery should be tested using the manually-
actuated Backup Battery Test. This can be because: